Technical specifications: 230V Powercord Incl. Tamperswitch
230 V connection cable for power supply from Milleteknik.
Technical specifications: Tamper switch
T-Tamperswitch is an accessory for battery backups which is a microswitch whic,h when connected to the motherboard, gives an alarm for tampering.
T-Tamperswitch can also be connected to external alarms, this is done in the devices that do not support tamper alarms on motherboards.
Connect mains
Before connecting, the supply circuit should be disconnected and voltage-free. Verify that the conductor area and cable type meet the applicable installation rules and that the strain relief and insulation levels comply with the requirements for 230 V AC
After connection, all screw connections should be checked and tightened. Tensioning shall only take place after mechanical protection, caps and housing have been reassembled and comply with the contact protection according to EN 62368-1
Secure F and N with cable ties.
Important
Protective earth (PE) must be connected to the PE terminal on the motherboard. The motherboard is grounded via its mounting points in the enclosure, ensuring proper potential equalization between PCB and enclosure. Also the cover is grounded through ground cable/earth braid between cover and enclosure to maintain continuity and EMC
Mains wiring must be kept separate from other wiring to avoid EMC interference.
The protective earth (PE) must be connected to the PE terminal on the motherboard. The motherboard is grounded via its mounting points in the enclosure, ensuring correct equipotential bonding between the circuit board and the enclosure. The cover is also grounded via a grounding cable / grounding braid between the cover and the enclosure to maintain continuity and EMC function.
Check that the marking on the circuit board matches the wiring order on the terminal block.

Connect the mains cable to the terminal block before it is re-inserted into the motherboard. Secure L (F in picture) and N with cable ties for electrical safety.
Letter | Explanation |
|---|---|
L | Fas, P 1:1. |
N | Neutral, P 1:2. |
PE | Proctected earth, P 1:3. |
Installation of tamper switch in M
Tamper switch in the cabinet of size M has its place on the right, in front of the cable entry.
IN there is no connection for tamper contact on circuit boards, so alarms from tamper switches must be connected externally.

Screw tamper switch in the roof of the cabinet.
There should be a washer between the white piece of plastic and the ceiling on the inside of the cabinet.
(If the washer is on the top, it is not possible to close the lid.)
Connect cables, tamper connector has no connection on circuit board.

Tamper switch and alarm class 3/4 according to SSF1014
Tamper switch must be attached to the wall to comply with alarm class 3/4 according to SSF1014.
The tamper switch must be connected to the system board.
If the distance is long from the wall when mounting in a rack, for example, a spaccer is needed. It is the installer's responsibility to install the appropriate spacer. The tamper switch in the cabinet must end when the cabinet door is closed. If the alarm goes off ("tamper alarm" / alarm to the control panel), the lever may need to be adjusted.
Tolerance levels for tamper contact: Alarm must be triggered when: Opening the cabinet door; > 1 mm. Breaking unit from wall:> 2.5 mm.

The picture shows location in battery backup and battery box.
Important
In case of alarm class 4, a vibration detector must also be fitted.
Installation of tamper switch in FLX S
Tamper switch placements
The T-Tamperswitch must be in one of two placements:
To alarm when the door is opened, then the T-Tamperswitch placed in the cabinet above the lock.
In the wall to give an alarm in the event of breakage of the entire enclosure T-tamperswitch must be mounted in the wall to meet the alarm class according to SSF. Note that sheet metal angle may differ from actually delivered.

Installation of tamper switch in FLX M
Tamper switch placements
The T-Tamperswitch must be in one of two placements:
To alarm when the door is opened, then the T-Tamperswitch placed in the cabinet above the lock.
In the wall to give an alarm in the event of breakage of the entire enclosure T-tamperswitch must be mounted in the wall to meet the alarm class according to SSF. Note that sheet metal angle may differ from actually delivered.

Installation of tamper switch in FLX L
Tamper switch placements
The T-Tamperswitch must be in one of two placements:
To alarm when the door is opened, then the T-Tamperswitch placed in the cabinet above the lock.
In the wall to give an alarm in the event of breakage of the entire enclosure T-tamperswitch must be mounted in the wall to meet the alarm class according to SSF. Note that sheet metal angle may differ from actually delivered.

Connection of tamper switch on PRO1
The battery backup should not be connected to mains when connecting.
Connector from T-Tamperswitch must be connected to J7 on the motherboard in the battery backup.
The connector from the T-Tamperswitch in the battery box must be connected to J11 on the motherboard in the battery backup.

Alarm from tamper
When the T-Tamperswitch is correctly installed, an alarm must be given on the cabinet door (Slow green flashing) to the Sabotage (tamper) battery backup.
If the battery backup is connected to an alarm-station then alarm for sabotage will be given when the micro switch connection is broken.
Connection of tamper switch on PRO2
The battery backup should not be connected to mains when connecting.
Connector from T-Tamperswitch must be connected to J3 on the motherboard in the battery backup.
The connector from the T-Tamperswitch in the battery box must be connected to J14 on the motherboard in the battery backup.

Alarm from tamper
When the T-Tamperswitch is correctly installed, an alarm must be given on the cabinet door (Slow green flashing) to the Sabotage (tamper) battery backup.
If the battery backup is connected to an alarm-station then alarm for sabotage will be given when the micro switch connection is broken.
Connection of tamper switch on PRO3
The battery backup should not be connected to mains when connecting.
Connector from T-Tamperswitch must be connected to J101 on the motherboard in the battery backup.
The connector from the T-Tamperswitch in the battery box must be connected to J7 on the motherboard in the battery backup.

Alarm from tamper
When the T-Tamperswitch is correctly installed, an alarm must be given on the cabinet door (Slow green flashing) to the Sabotage (tamper) battery backup.
If the battery backup is connected to an alarm-station then alarm for sabotage will be given when the micro switch connection is broken.
Adjustment of tamper switch
![]() |
The tamper switch lever must be in the closed position when the cabinet door is closed. If the alarm goes off ("tamper alarm"), the lever may needs to be adjusted.
The lever is adjusted by the following steps:
Pinch with pliers in the middle of the lever.
Carefully adjust the lever in the desired direction (up / down).
Check by closing the door. A click is heard when the contact is closed.
Notice
Tamper switch will not give an alarm when closed and locked the door.
Connection of tamper devices that do not have a communcation connection
If there is no connection on the circuit board, as in , alarms from tamper switches must be connected to an external alarm.
Technical data 230V Power cord Incl. Tamper switch
Article name | 230V Power cord Incl. Tamper switch |
Item number | A-00002301FA01 |
Email number | 5257446 |
Type | 230 V connection cable for battery backup. |
Length | 2 meters |
Technical data: Tamper switch
Name | T-Tamperswitch |
Type | Microswitch |
Voltage | 12 V / 24 V |
About translation of this document
User manual and other documents are in the original language in Swedish. Other languages may be machine translated and/or not reviewed, errors may occur.