| Recommended environment |
Indoor class 1. Ambient temperature: +5°C to +40°C.
|
| Security class (IP-klass) |
IP32
|
| Recommended mounting |
Wall or 19" rack
|
| Height units |
10RU
|
| Dimensioner (Höjd x Bredd x Djup) |
444 x 437 x 212 mm
|
| Number of cable ports |
4, possible to have outlet holes on rear
|
| Color |
Black powder covered metal
|
| Built in cooling fan |
Yes
|
| Voltage in (V) |
230 – 240 VAC, 50-60 Hz
|
| Current out |
27.3 VDC (24 V)
|
| Max current |
10 A
|
| Available charging current (A) |
Dependent upon power outlet, though max 6 A
|
| Rated power |
240 W
|
| Ripple i normal mode |
120 mVp-p
|
| Efficiency |
89 %
|
| heat generation at 50% / 80% of rated power |
17 W / 27 W
|
| Current in (A) |
2 A
|
| Number of unsecured (load-) outputs |
2
|
| Type of fuse / ouput |
2 15A flat pin fuses
|
| Deep discharge of battery occurs at |
21 VDC
|
| Battery type |
12 V maintenance free AGM battery
|
| Recommended battery |
2 UPLUS 12 V, 45 Ah batteries
|
| Batteries included |
Yes
|
| Protection against |
Deep discharge of batteries, Excessive temperature, Over voltage, Overload, Short circuit
|
| Alarm via |
Changeover relay, RS232
|
| Alarm functions |
Battery disconnected (10 sec), Charger error overvoltage, Charger error undervoltage, Delayed power grid failure alarm (10 sec), External alarm via pin list (optional card), Fuse failure (buzzer alarm, alarm output 2), Low system voltage, Old battery, Tampering
|
| Support for communication via |
RS-232
|
| Information via protocol |
Alarm for high / low temperature, Alarm from temperature sensor, All standard alarm functions, Fan error, Highest and lowest battery voltage since start, Highest and lowest temperature since start, Minimum / Max / Average temperature the latest hour / 72 hours, Minimum / Max / Average voltage the latest / 1 hour / 24 hours / 72 hours, Minimum / Max / Average voltage the latest 1 hour / 72 hours, Possibility to set alarm levels
|
| Tamper switch |
Yes
|
| Lockable enclosure |
Yes, two keys included.
|
| Normal dlivery time |
3-5 days
|
| Guarantee period |
2 years
|
| Warranty conditions 5 year warranty |
Average load shall not exceed 80 % of power supply's rated capacity-, Battery backup shall be used together with UPLUS 10+ Design Life batteries., Surrounding temperature shall not exceed 32°C., The fan shall be cleaned annually and replaced if needed.
|
| Certified in accordance with |
Meets requirements of alarm class 4, SSF 1014, edition 5
|
| Certificate number (SBSC) |
20-117
|
| Product meets requirements in accordance with |
CE directive in accordance with:765/2008, EMC Directive 2014/30EU, Emission: EN61000-6-:2001, EN55022:1998:-A1:2000, A2:2003 Class B, EN61000-3-2:2001, Immunity: EN61000-6-2:2005, EN61000-4-2, -3, 4, -5, -6, -11. SS-EN 50 130-4:2011 Edition 2 & SSF1014 Alarm class 1-2 (Burgler alarm), Low voltage directive: 2014/35/EU
|
| Producer |
Milleteknik AB
|
| Country of origin |
Sweden
|
| Not |
All specifications subject to change in event of product changes or incorrect data
|